SKU: J5AC5030A1000AA-J5AH5E36A1B00AA-5JAYHTR1A05BKA
2.5 Ton15.2 SEER2Electric HeatR454B
$3,190.00
Free Shipping
Full Warranty
Expert Support
Shipping & Delivery
Free shipping on complete systems. Most orders ship within 1–3 business days. Local pickup available at our Ocala, FL warehouse for additional savings.
Warranty Information
All units come with full manufacturer warranty covering parts. Register your warranty within 60 days of purchase for extended coverage.
R-454B Refrigerant 2.5 Ton · 15.2 SEER2 AC 5 kW Heat Kit Included Up to 10-Year Parts Warranty 208/230V Single-Phase

Performance at a Glance

2.5
Ton
Nominal Capacity
15.2
SEER2
Cooling Efficiency
5
kW
Electric Heat
75
dB
Outdoor Sound Rating

Straightforward comfort for a modest single-family home: a 2.5 ton Oxbox air conditioner, a matched upflow air handler, and a 5 kW electric heat kit, all shipped together.

Key Features

This Oxbox 2.5 ton air conditioner split system is rated at 15.2 SEER2, Oxbox's higher efficiency tier. The extra efficiency pays off most where the system runs for much of the year. For heat, the 5 kW electric heat kit mounts inside the air handler and warms air through the same ducts that carry your cooling. This matchup uses the J5AH5E36A1B00AA air handler, an upflow unit with a 1/2 HP blower motor. The 2.5 ton capacity puts it in the range typically used for modest single-family homes and larger condos. Everything runs on R-454B refrigerant and 208/230V single-phase power, and it's approved for installation in both the DOE North and South regions.

  • Rotary compressor: a compact, efficient compressor design well suited to this capacity range.
  • Upflow air handler with built-in evaporator coil: matched to this outdoor unit, with a 1/2 HP blower motor moving air through your ductwork.
  • Straightforward electrical: 17.6 A minimum circuit ampacity on the outdoor unit keeps breaker and wire sizing simple for a 2.5 ton install.
  • 15.2 SEER2 efficiency: a step above minimum efficiency, which adds up in climates where the AC runs most of the year.
  • 5 kW electric heat kit, included: covers your heating needs without a separate furnace, and arrives with the rest of the system.
  • R-454B refrigerant: a lower global warming potential refrigerant that meets current EPA requirements for new systems.

What's Included in This System

Three matched components shipped as one system

1
Outdoor Condenser
J5AC5030A1000AA
Sits on a pad outside your home and holds the rotary compressor, coil, and fan. Does the heavy lifting of the cooling cycle.
  • Tonnage2.5 Ton
  • SEER2 Rating15.2
  • CompressorRotary
  • RefrigerantR-454B
  • Sound Rating75 dB
2
Indoor Air Handler
J5AH5E36A1B00AA
The indoor half of the system: evaporator coil, blower, and the cabinet that holds the heat kit, all in one unit.
  • AirflowUpflow
  • Blower Motor1/2 HP
  • Blower FLA3.3 A
  • RefrigerantR-454B
3
Electric Heat Kit
5JAYHTR1A05BKA
Electric heat strip made for the air handler. Supplies the system's heating, so you get warm air through the same ducts that carry your cooling.
  • Heat Output5 kW
  • Mounts InAir Handler
  • RolePrimary Electric Heat

Specifications

System
System Type Air Conditioner Split System
Nominal Capacity 2.5 Ton
SEER2 Rating 15.2
Refrigerant R-454B
Heating 5 kW electric heat (included)
DOE Regions North & South
Outdoor Unit Electrical
Voltage 208/230V, Single Phase
Minimum Circuit Ampacity (MCA) 17.6 A
Compressor RLA 12.7 A
Compressor LRA 58 A
Condenser Fan Motor 1/3 HP · 1.7 FLA
Indoor Unit & Refrigerant Lines
Air Handler Airflow Upflow
Blower Motor 1/2 HP · 3.3 FLA
Liquid Line 3/8"

Warranty

Backed by Oxbox's manufacturer warranty

5
Year Parts (Standard)
10
Year Parts (When Registered)

Register your system with Oxbox after installation to extend parts coverage from 5 to 10 years. See Oxbox's official warranty documents for complete terms and conditions.

Common Questions

What else do I need for installation?
Plan on a copper line set sized for your run, a condenser pad, an outdoor disconnect, electrical wiring, and a thermostat. Refrigerant work must be done by a licensed HVAC technician.
How does this system heat?
This is an air conditioner, so heating comes from the included 5 kW electric heat strip inside the air handler. It's a simple, reliable setup for areas with short, mild winters. If you heat for much of the year, a heat pump system will usually cost less to run.
Is 2.5 tons the right size for my home?
2.5 tons is a common fit for modest single-family homes and larger condos, but square footage alone isn't a reliable guide. Insulation, windows, sun exposure, and ductwork all matter. A Manual J load calculation from your installer is the best way to confirm sizing before you buy.
14.3 or 15.2 SEER2: which should I choose?
Both meet current efficiency requirements. The 15.2 SEER2 systems cost a bit more up front and use less electricity to cool, so they make the most sense where the system runs much of the year. The 14.3 SEER2 systems keep the purchase price lower. This system is the 15.2 SEER2 version.