Oxbox

Oxbox By Trane 2.0 Ton 14.3 SEER2 R454B Air Conditioner Split System w/ Front Return Wall Hung | J5AC5024A1000AA-5JMM4A0A24S21SA-5JAYHTR1J05BKA

SKU: J5AC5024A1000AA-5JMM4A0A24S21SA-5JAYHTR1J05BKA
2.0 Ton14.3 SEER2Electric HeatR454B
$2,759.00
Free Shipping
Full Warranty
Expert Support
Shipping & Delivery
Free shipping on complete systems. Most orders ship within 1–3 business days. Local pickup available at our Ocala, FL warehouse for additional savings.
Warranty Information
All units come with full manufacturer warranty covering parts. Register your warranty within 60 days of purchase for extended coverage.
R-454B Refrigerant 2 Ton · 14.3 SEER2 AC Wall-Hung · Front Return Up to 10-Year Parts Warranty 208/230V Single-Phase

Performance at a Glance

2.0
Ton
Nominal Capacity
14.3
SEER2
Cooling Efficiency
5
kW
Electric Heat
1/5
HP
Indoor Blower Motor

A closet-friendly Oxbox system for small homes, condos, and apartments: 2 ton air conditioner, wall-hung air handler with front return, and a 5 kW heat kit, all matched and shipped together.

Key Features

This Oxbox 2 ton air conditioner split system is rated at 14.3 SEER2, Oxbox's standard efficiency tier. For heat, the 5 kW electric heat kit mounts inside the air handler and warms air through the same ducts that carry your cooling. Indoors, the wall-hung air handler takes return air straight through a grille on its front panel, so it fits closets that weren't built for a floor-standing cabinet and return plenum. It is a practical match for small homes, condos, and apartments, pending a load calculation from your installer. Everything runs on R-454B refrigerant and 208/230V single-phase power, and it's approved for installation in both the DOE North and South regions.

  • Rotary compressor: a compact design that suits smaller-capacity systems like this one.
  • Wall-hung air handler: mounts directly on the wall, freeing up floor space and making it a direct path for replacing an existing wall-mounted closet unit.
  • 5 kW electric heat kit, included: covers your heating needs without a separate furnace, and arrives with the rest of the system.
  • R-454B refrigerant: the low-GWP A2L refrigerant replacing R-410A in new residential equipment.
  • Front return air: air returns through the front of the cabinet, eliminating the need for a separate return plenum or stand underneath.
  • Straightforward electrical: 15.3 A minimum circuit ampacity on the outdoor unit keeps breaker and wire sizing simple for a 2 ton install.

What's Included in This System

Three matched components shipped as one system

1
Outdoor Condenser
J5AC5024A1000AA
The outdoor half of the system. Houses the rotary compressor, outdoor coil, and condenser fan, and rejects the heat pulled from your home.
  • Tonnage2 Ton
  • SEER2 Rating14.3
  • CompressorRotary
  • RefrigerantR-454B
  • Sound Rating73 dB
2
Wall-Hung Air Handler
5JMM4A0A24S21SA
Wall-mounted indoor unit with a front return grille, built-in evaporator coil, and blower. Hangs in a closet or utility space and houses the electric heat kit.
  • MountingWall-Hung
  • Return AirFront Return
  • Blower Motor1/5 HP
  • Blower FLA1.3 A
3
Electric Heat Kit
5JAYHTR1J05BKA
Electric heat strip made for the wall-hung air handler. Supplies the system's heating, so you get warm air through the same ducts that carry your cooling.
  • Heat Output5 kW
  • Mounts InWall-Hung Air Handler
  • RolePrimary Electric Heat

Specifications

System
System Type Air Conditioner Split System
Nominal Capacity 2 Ton
SEER2 Rating 14.3
Refrigerant R-454B
Heating 5 kW electric heat (included)
Air Handler Style Wall-hung, front return
DOE Regions North & South
Outdoor Unit Electrical
Voltage 208/230V, Single Phase
Minimum Circuit Ampacity (MCA) 15.3 A
Compressor RLA 11.3 A
Compressor LRA 55 A
Condenser Fan Motor 1/3 HP · 1.3 FLA
Indoor Unit & Refrigerant Lines
Blower Motor 1/5 HP · 1.3 FLA
Liquid Line 3/8"

Warranty

Backed by Oxbox's manufacturer warranty

5
Year Parts (Standard)
10
Year Parts (When Registered)

Register your system with Oxbox after installation to extend parts coverage from 5 to 10 years. See Oxbox's official warranty documents for complete terms and conditions.

Common Questions

What else do I need for installation?
Plan on a copper line set sized for your run, a condenser pad, an outdoor disconnect, electrical wiring, wall-mounting hardware, a return filter, and a thermostat. Refrigerant work must be done by a licensed HVAC technician.
Will this fit where my old wall-mounted unit was?
It's designed for exactly that kind of space: closets and utility areas where the air handler hangs on the wall and pulls return air through its front. Before ordering, compare the cabinet dimensions and duct connection points against your existing unit, and have your installer confirm clearances and wall support.
What does front return mean?
Return air (the air pulled back from your living space to be cooled or heated) enters through a filter grille on the front of the air handler. That removes the need for a return plenum or platform under the unit, which is what lets it work in shallow closets and wall-mounted setups.
How does this system heat?
This is an air conditioner, so heating comes from the included 5 kW electric heat strip inside the air handler. It's a simple, reliable setup for areas with short, mild winters. If you heat for much of the year, a heat pump system will usually cost less to run.
14.3 or 15.2 SEER2: which should I choose?
Both meet current efficiency requirements. The 15.2 SEER2 systems cost a bit more up front and use less electricity to cool, so they make the most sense where the system runs much of the year. The 14.3 SEER2 systems keep the purchase price lower. This system is the 14.3 SEER2 version.