Complete Package Units Insane Deals
Every complete system, every tonnage, Goodman and Ace Air. Priced to move, and these won't last.
- Free shipping on complete systems
- 10-year registered warranty
- Ships from Ocala in 1-3 days
- 4 systems on sale
Ace Air
Complete Ace Air 3 Ton 13.4 SEER2 Mobile Home Air Conditioning Package Unit
3 Ton13.4 SEER2R-32Electric Heat
$3,099$4,053
Save $954✓ Free shipping includedGrab this deal
SaleBest value
Ace Air
Complete Ace Air 3 Ton 13.4 SEER2 Heat Pump Package Unit
3 Ton13.4 SEER2R-32Heat Pump
$3,499$5,056
Save $1,557⚠ Only 1 left in stock✓ Free shipping includedGrab this deal
Sale
Goodman
Complete Goodman 3 Ton 13.4 SEER2 Mobile Home Air Conditioning Package Unit
3 Ton13.4 SEER2R-32Electric Heat
$4,053
See price in cart✓ Free shipping includedGrab this deal
Sale
Goodman
Complete Goodman 3 Ton 13.4 SEER2 Heat Pump Package Unit
3 Ton13.4 SEER2R-32Heat Pump
$5,056
See price in cart⚠ Only 1 left in stock✓ Free shipping includedGrab this deal
About Package Units
All-in-one HVAC systems for mobile homes, tight lots, and rooftop installs
A package unit combines everything an HVAC system needs — condenser, evaporator coil, blower, and often a heat source — into one outdoor cabinet. Instead of running refrigerant lines between an outdoor condenser and indoor air handler, the package unit handles the whole refrigeration cycle outside and just pushes conditioned air through your ducts via a single supply and return connection.
Every package unit on this page is factory-charged, fully assembled, and shipped from our Ocala, FL warehouse — usually out the door within 1-3 business days. We carry Goodman (a Daikin brand) and our own Ace Air private label, with configurations spanning AC-only, heat pump, gas/electric, and mobile-home-approved electric heat variants.
The first decision is unit type (AC vs. heat pump vs. gas/electric vs. mobile home). From there, match tonnage to your home's cooling load and refrigerant to your long-term preference. Package units are installed by licensed HVAC contractors, same as split systems.
What to look at when choosing
Five things to decide before you buy — starting with the big one: unit type
Unit type (this is the big decision)
Packaged AC = cooling only, needs separate heat source. Packaged heat pump = heats and cools year-round. Gas/electric package = AC + gas furnace in one cabinet. Mobile home electric = AC with built-in electric heat strips, specifically approved for manufactured home installations.
Tonnage (cooling capacity)
Same sizing rule as split systems — 1 ton is about 12,000 BTU/h or 600 sq ft. Package units are most commonly 2-5 tons for residential use. Mobile homes are typically 1.5-3 tons.
SEER2 (efficiency)
Same DOE test standard as split systems. Higher SEER2 means a lower electric bill. Every package unit on this page meets the federal minimum of 13.4 SEER2, which applies in all 50 states, including Florida. Unlike split systems, package units have no higher regional minimum in the South. Want more efficiency? Call us at (352) 438-8992 about higher-SEER2 options.
Refrigerant type
R-32 and R-454B are the current compliant refrigerants. R-410A is legacy. Since package units are all-in-one (refrigerant lines are sealed inside the cabinet), there's no indoor unit to match — just pick the refrigerant you prefer for long-term service.
Installation surface
Most package units install on a concrete pad at ground level. Rooftop installation is common on mobile homes and small commercial buildings — look for 'down-flow' supply/return configuration. Always check your local building code for setback requirements and hurricane strapping (Florida especially).
R-32 vs. R-410A refrigerant
Why we're moving away from R-410A and what it means for package unit buyers
Frequently asked questions
Common questions about package unit selection, installation, and operation
How fast will my unit ship?
Order by noon ET on a business day and Florida orders ship the same day. Delivery is typically 1-4 business days, with tracking and a scheduled delivery appointment. Local pickup in Ocala is also available.
Are 13.4 SEER2 package units legal in Florida?
Yes. The DOE's higher southern minimum (14.3 SEER2) applies to split systems only. Single-package air conditioners and heat pumps have a 13.4 SEER2 minimum nationwide, so every package unit we sell can be installed new in Florida and every other state.
What's a package unit, and how is it different from a split system?
A package unit combines every part of an HVAC system — compressor, condenser coil, evaporator coil, blower, and sometimes a heat source — into a single outdoor cabinet. A split system separates the condenser (outside) from the air handler or coil (inside), connected by refrigerant lines. Package units are simpler to install (no indoor unit, no line set run), more forgiving of tight homes where there's no room for an indoor cabinet, and the default choice for mobile homes. Split systems are typically more efficient and quieter.
When should I choose a package unit over a split system?
Three common scenarios: (1) Mobile homes — most are designed around package units, with ducting that connects directly to a rooftop or pad-mounted unit; (2) Tight homes or condos where there's no indoor space for an air handler; (3) Replacement — if your current system is a package unit, a new package unit is usually the drop-in replacement. Split systems generally win on efficiency and sound, so if you're building new and have the space, consider both options.
What's the difference between 'electric heat' and 'gas/electric'?
Electric heat means the unit has electric resistance heat strips (typically 5kW-15kW) built into the package cabinet — reliable and simple, but more expensive to run than gas in most markets. Common on mobile home units. Gas/electric means the unit has a natural gas or propane furnace burning in the cabinet for heating, with electric cooling — cheaper to operate in cold climates with affordable gas. Heat pump packages use the refrigeration cycle to heat and cool, most efficient overall but may need electric backup in the coldest climates.
What are RLA, LRA, MCA, and MOCP on the spec sheet?
These are the electrical specs your installer needs to wire the unit. RLA (Rated Load Amps) is normal running current. LRA (Locked Rotor Amps) is startup current — briefly much higher. MCA (Minimum Circuit Ampacity) is the minimum wire size needed. MOCP (Maximum Overcurrent Protection) is the largest breaker that can legally protect the circuit. You don't need to memorize these — your licensed installer will use them to spec the electrical. Just make sure your home has a breaker panel with enough open capacity.
Does Ace Air Direct ship package units nationwide?
Yes. We ship package units to all 48 contiguous states from our warehouse in Ocala, FL. Because they're larger and heavier than split-system condensers, package units ship via freight carrier with lift-gate service available. Most orders leave within 1-3 business days. Local pickup is available in Ocala for additional savings — package units fit easily in a pickup truck bed or small trailer.